Advertisement

Hemostasis Valves

January 16, 2013 10:56 am | Qosina | Product Releases | Comments

Qosina is pleased to announce the addition of three competitively priced 9 FR Hemostasis Valves (#80325, #80326, #80327) to their line of Guide Wire Kit Accessories. All three feature a clear polycarbonate body...

LISTED UNDER: Other

One Handed Hemostasis Valve Y Connector

January 4, 2013 11:36 am | Qosina | Products

Qosina is pleased to present the latest innovation in component technology, a One Handed Hemostasis Valve Y Connector (#80448) that allows independent manipulation of multiple guidewires. The genuine one hand control lever action allows for lock and release with light fingertip pressure for three positions; open, semi-open, and closed. A satisfyingly powerful ‘click’ clearly identifies the valve position by acoustic and tactile feedback enabling easy and efficient operation. The housing is made from high quality polycarbonate and polyoxymethylene, which has both high clarity and temperature resistance. The silicone valve fits 0 FR – 9 FR (0 inch-0.118 inch) (0 mm-3 mm) guidewires and aids in controlling backflow. The rotating male luer lock minimizes tubing kinks, while the female luer lock sideport provides the ability to flush out the line or check pressure. Wire Lock Adapters (#80449 and #80450) work in conjunction with this Hemostasis Valve for applications involving multiple guidewires. These adapters feature an integrated lock and release function, which enables independent wire manipulation by utilizing one or more adapters. Simply clip the adapter on the Hemostasis Valve and lock the wire into the adapter to hold it in position while inserting or using other wires.

LISTED UNDER: Guidewires | Other

Swabbable Needleless Injection Site with a One Way Valve

January 4, 2013 11:30 am | Qosina | Products

Qosina recently added a Swabbable Needleless Injection Site #80189 to their line. Unlike other needleless sites that allow for bidirectional flow, this site incorporates a one way valve enabling this component to be used for injection only and will prevent retrograde flow. When the connection is removed, the valve will reseal against backflow even when used with viscous solutions. This injection site features a needleless female luer port to a male luer slip and is equipped with a luer activated valve that allows any standard male luer to open the connection. Composed of Polycarbonate, Silicone and Polyisoprene, the connector is made of biocompatible materials. All materials are latex-free, DEHP-Free and PVC-Free. By eliminating the use of sharp needles for accessing IV lines, the needleless connector is designed to prevent accidental needle sticks. It poses an economical alternative to other needleless sites and is available with a low minimum purchase requirement. The luer fittings are also compatible with the ISO 594 luer standards for both standard male luer and male luer slip fittings.

LISTED UNDER: Injection Sites
Advertisement

Qosina In-Line Check Valve

January 4, 2013 11:27 am | Qosina | Products

Qosina recently announced the addition of a competitively priced In-Line Check Valve (#80190) to their extensive line of stock components. In stock and available for immediate delivery, the DEHP Free, acrylic In-Line Check Valve features a Latex Free silicone diaphragm that allows flow in one direction and will prevent retrograde flow (back pressure tested to 45 psi). The In-Line Check Valve has a cracking pressure of 0 psi- 0.7 psi, and features a versatile design making it a superior choice for inclusion by original equipment manufacturers as a component in various applications. Featuring a thin profile and low priming volume, the In-Line Check Valve has a white inlet and clear outlet. The tubing ports measure 0.13 inch – 0.138 inch OD (3.3 mm – 3.5 mm).

LISTED UNDER: Check

Qosina Anti-Slip Boot

January 4, 2013 11:25 am | Qosina | Products

Qosina is pleased to announce the addition of an Anti-Slip Boot (#51599) to its extensive line of stock components. The new Anti-Slip Boot helps prevent luer fittings from slipping apart, and works with most standard luer fittings. Made from medical grade silicone and applicable for autoclave, gamma and EtO sterilizing, the Anti-Slip Boot measures 11/32 inch ID x ½ inch OD x ¾ inch (0.343 inch x 0.5 inch x 0.75 inch, 8.7 mm x 12.7 mm x 19.05 mm). Designed to maintain the integrity of a luer fitting assembly, this simple solution helps prevent loss and contamination due to accidental disconnection of luer parts.

LISTED UNDER: Luers

Analytical Electronic Valves

January 3, 2013 10:24 am | Clippard Instrument Laboratory, Inc. | Product Releases | Comments

Clippard Instrument Laboratory, Inc. introduces the new Analytical Series electronic valves. Available in 2-way or 3-way, normally-closed or fully ported, the valves are designed for the specific needs of the analytical industry...

LISTED UNDER: Gas Valve | Other

Precision Molded Medical Components and Assemblies

December 20, 2012 10:43 am | Minnesota Rubber & Plastics | Product Releases | Comments

Medical equipment manufacturers seeking a qualified manufacturing partner will find this brochure particularly useful. It details Minnesota Rubber and Plastics’ 65 years of experience in the medical components...

LISTED UNDER: Injection Molding | Molding | Cleanroom Assembly

High-Purity TPV Medical Elastomer Range

December 17, 2012 11:11 am | Teknor Apex Company | Product Releases | Comments

Teknor Apex Company has developed two high-hardness grades in its Medalist® MD-200 series of thermoplastic vulcanizate (TPV) elastomers, extending the already broad durometer range...

LISTED UNDER: Thermoplastic Elastomers | Control | Handles and Knobs
Advertisement

Pumps Offer Reliability, Safety to Gas, Leak Detection Warning Devices

December 14, 2012 11:57 am | Thomas Division | Product Releases | Comments

Designed for handheld gas and leak detection warning devices, the new 1010 Series diaphragm compressors and pumps from Thomas have been tested for 4,000 hours of nonstop operation providing the utmost in reliability and safety.

LISTED UNDER: Compressor | Diaphragm Pump | Compressor

Anti-Slip Boot

December 12, 2012 3:44 pm | Qosina | Product Releases | Comments

Qosina is pleased to announce the addition of an Anti-Slip Boot (#51599) to its extensive line of stock components. The new Anti-Slip Boot helps prevent luer fittings from slipping apart...

LISTED UNDER: Connectors | Luers | Fittings

High Airflow Sensors

December 12, 2012 3:19 pm | Product Releases | Comments

Honeywell announced it has expanded its Zephyr™ airflow sensor HAF Series portfolio with new digital versions that provide airflow ranges of 0 to 20 SLPM (Standard Liters per Minute) and 0 to 200 SLPM.

LISTED UNDER: Flow | Fittings | Air Pump

OEM Pumps Designed for the Surgical Ablation Market

December 12, 2012 10:03 am | Watson Marlow Pumps Group | Product Releases | Comments

Watson-Marlow Pumps Group is unveiling a new range of 400RXMD OEM pumps, specifically designed for the surgical ablation market, in booth #1713 at MD&M West, from February 12-14, 2013, at the Anaheim Convention Center, in Anaheim, CA.

LISTED UNDER: Other

Non-DEHP PVC Hose

December 11, 2012 11:35 am | Newage Industries, Inc. | Product Releases | Comments

NewAge Industries announces that its signature product, Nylobrade braid-reinforced PVC hose, is manufactured from a PVC compound that is free of DEHP and other plasticizers.

LISTED UNDER: PVC Tubing | Reinforced | PVC Tubing

Pneumatic Pinch Valves

December 10, 2012 10:37 am | Acro Associates | Product Releases | Comments

Acro Associates, Inc. today introduced two new models, the 935HF (high force) and 936 pneumatic pinch valve designed to meet the needs of single-use bioprocessing systems.

LISTED UNDER: Pinch Valve | Control | Flow

KNF Neuberger, Inc. - Pump offers higher flow in compact package

December 6, 2012 10:54 am | KNF Neuberger, Inc. | Products

A new KNF micro diaphragm gas-sampling pump, type NMP015.1.2, uniquely integrates head connections inside the housing for improved pneumatic performance in a compact and leak-tight package. This optimized design produces less pulsation and additionally allows for the housing to be closed and sealed for significant reduction in audible noise. The pump ideally suits portable, battery-operated equipment used in a wide range of OEM applications, including gas sampling, explosives detection devices, anesthesia systems, and medical analyzers, among others. Among features, the pump's elastomeric diaphragm promotes high efficiency and delivers oil-free operation without any risk of contaminating the sampled gas. Pumps can be specified either with an ironless core DC motor or with a brushless DC motor offering longer service life. PEEK housings and pump heads contribute high stiffness and temperature and chemical resistance. Depending on model, these pumps can achieve flow rates to 2.1 l/m, vacuum to 650 mbar (11 in. Hg) absolute, and continuous pressure to 0.6 bar g (9 psig). All are engineered to perform maintenance-free with low power requirements and are supplied ready for installation to operate in any position. Chemically resistant versions are available and pumps can otherwise be customized to meet particular application demands.

LISTED UNDER: Air Pump | Compressor | Diaphragm Pump

Pages

X
You may login with either your assigned username or your e-mail address.
The password field is case sensitive.
Loading